Boiler feed pump for the maintenance of condensate pump

You are here: Home >> NEWS >> Industry news

Boiler feed pump for the maintenance of condensate pump

Release date:2015-06-15 15:48 Source:http://www.hotelsuninns.com Views:

The daily maintenance of the modern boiler feed pump of the condensate pump must take the fault prevention as the goal, establish the scientific curing system and the system, in order to instruct the daily maintenance work of the water pump.. The establishment of a water pump parts fault and replace records, detailed grasp the damage to the parts of time, for later in parts to life change in time, avoid the parts (for example: Bearing) damage found not promptly on the unit causing damage. In addition, we should strengthen the maintenance of the lubrication system of the feed pump, check the oil quantity regularly, lubricate the parts in time, and avoid the occurrence of dry grinding.. Add lubricating oil before you pay attention to check the oil and add the cleanliness of the mouth to avoid the process of adding impurities into the damaged bearings. In maintenance should pay attention to the water pump system on the pipeline inspection and maintenance, timely the leak plugging, pipe outside antirust coating to carry out regular inspection, the timely spray on the spalling of the coating, in order to ensure that pipeline corrosion. Maintenance of the water pump and water treatment system for inspection and maintenance.

Heads of the shell is in a bowl shape shell or spiral shell, secondary and final shell is bowl shaped shell; pump shaft with radial bearing, rotor axial load can be borne by the pump itself thrust bearing, and can also be borne by the motor; shaft seals for packing seal or mechanical seal, pump rotor system with two shaft, shaft is connected to the card ring cylinder type coupling, pump connection for elastic column pin coupling or rigid coupling connection; inhalation and spit out the interface are respectively located in the pump barrel and spit out the seat, and a 180 DEG from the horizontal layout (according to the integer times of 15 DEG arbitrary displacement).

The outlet portion is composed of a nozzle, a pump seat, etc. the drive shaft of the pump is passed through the center of the part; and the fluid flowing through the pump is pumped outside the pump pressure pipe after the partial. Pump seat is provided with a sealed box body, a pressure relief hole, steam removing holes; pressure relief hole to seal chamber pressure is reduced to the minimum; off steam hole in the pump barrel is arranged in a gas discharge in a timely manner to the condenser. Condensate pump


condensate pump

Related tags:condensatepump